Filtros de búsqueda

Lista de obras de Michael Morlock

A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw

artículo científico publicado en 2011

A description of spinal fatigue strength.

artículo científico publicado en 2016

A new algorithm for estimating the rod volume fraction and the trabecular thickness from in vivo computed tomography.

artículo científico publicado en 2016

A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: design rationals and study design of an international clinical trial

artículo científico publicado en 2008

Abrasive water jet cutting as a new procedure for cutting cancellous bone--in vitro testing in comparison with the oscillating saw.

artículo científico publicado en 2004

Absence of surface roughness changes after insertion of one type of matte cemented femoral component during 2 to 15 years.

artículo científico publicado en 2003

Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair

artículo científico publicado en 2015

Adaptation of mechanical, morphological, and biochemical properties of the rat growth plate to dose-dependent voluntary exercise

artículo científico publicado en 2004

Advances in Porous Biomaterials for Dental and Orthopaedic Applications.

artículo científico publicado en 2010

An in vitro comparison of tibial tray cementation using gun pressurization or pulsed lavage

artículo científico publicado en 2014

Analysis of morphology and gait function after intraarticular calcaneal fracture.

artículo científico publicado en 1993

Artificial composite bone as a model of human trabecular bone: the implant-bone interface.

artículo científico publicado en 2006

Assembly force and taper angle difference influence the relative motion at the stem-neck interface of bi-modular hip prostheses.

artículo científico publicado en 2016

Basic principles and uniform terminology for the head-neck junction in hip replacement

artículo científico publicado en 2014

Biomechanical Effects of a Dynamic Topping off Instrumentation in a Long Rigid Pedicle Screw Construct.

artículo científico publicado en 2017

Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

artículo científico publicado en 2013

Biomechanical analysis of atlas fractures: a study on 40 human atlas specimens

artículo científico publicado en 2008

Biomechanical evaluation for mechanisms of periprosthetic femoral fractures

artículo científico publicado en 2011

Biomechanical evaluation of 3 stabilization methods on acromioclavicular joint dislocations.

artículo científico publicado en 2013

Biomechanical evaluation of peri- and interprosthetic fractures of the femur

scientific article published on 01 June 2010

Biomechanical modelling of impact-related fracture characteristics and injury patterns of the cervical spine associated with riding accidents

artículo científico publicado en 2015

Biomechanics of a new short-stemmed uncemented hip prosthesis: An in-vitro study in human bone

artículo científico publicado en 2006

Biomechanics of short hip endoprostheses--the risk of bone failure increases with decreasing implant size.

artículo científico publicado en 2010

Bioresorption and degradation of biomaterials

scientific article published on 01 January 2012

Bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: an in vitro comparison of mechanical behavior under failure tensile loading and cyclic submaximal tensile loading

artículo científico publicado en 2002

CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis

artículo científico publicado en 2017

Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures--a biomechanical cadaver study.

artículo científico publicado en 2013

Cement augmentation versus extended dorsal instrumentation in the treatment of osteoporotic vertebral fractures: a biomechanical comparison

artículo científico publicado en 2016

Cement mantle defects in total hip arthroplasty: influence of stem size and cementing technique.

artículo científico publicado en 2007

Cementation and interface analysis of early failure cases after hip-resurfacing arthroplasty.

artículo científico publicado en 2012

Clinical and Wear Analyses of 9 Large Metal-on-Metal Total Hip Prostheses

artículo científico publicado en 2016

Comparison of different cement application techniques for tibial component fixation in TKA

artículo científico publicado en 2014

Compressive strength of elderly vertebrae is reduced by disc degeneration and additional flexion.

artículo científico publicado en 2014

Consistent hydration of intervertebral discs during in vitro testing

scientific article published on 13 November 2006

Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers

artículo científico publicado en 2020

Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?

scientific article published on 01 June 2001

Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

artículo científico publicado en 2016

Deformation characteristics and eigenfrequencies of press-fit acetabular cups

artículo científico publicado el 1 de enero de 2011

Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation.

artículo científico publicado en 2006

Deformation of press-fitted metallic resurfacing cups. Part 2: Finite element simulation.

artículo científico publicado en 2006

Design parameters and the material coupling are decisive for the micromotion magnitude at the stem-neck interface of bi-modular hip implants.

artículo científico publicado en 2013

Development of a dynamic model for ventral hernia mesh repair.

artículo científico publicado en 2014

Does impaction matter in hip resurfacing? A cadaveric study

artículo científico publicado en 2010

Dream contents of sleep disordered patients

artículo científico publicado el 1 de febrero de 1998

Duration and frequency of every day activities in total hip patients

artículo científico publicado en 2001

Dynamic intermittent strain can rapidly impair ventral hernia repair

artículo científico publicado en 2015

EMED Scientific Meeting ESM

scientific article published on 18 April 2008

Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws.

artículo científico publicado en 2004

Effect of tibial tray design on cement morphology in total knee arthroplasty

artículo científico publicado en 2014

Effects of impaction on cement mantle and trabecular bone in hip resurfacing

artículo científico publicado en 2010

Effects of insulin therapy on porosity, non-enzymatic glycation and mechanical competence in the bone of rats with type 2 diabetes mellitus

artículo científico publicado en 2016

Effects of long-term alendronate treatment on bone mineralisation, resorption parameters and biomechanics of single human vertebral trabeculae.

artículo científico publicado en 2014

Effects of parathyroid hormone on bone mass, bone strength, and bone regeneration in male rats with type 2 diabetes mellitus

scientific article published on 27 January 2014

Effects of parathyroid hormone on cortical porosity, non-enzymatic glycation and bone tissue mechanics in rats with type 2 diabetes mellitus

artículo científico publicado en 2015

Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique

artículo científico publicado en 2016

Erythropoietin loaded microspheres prepared from biodegradable LPLG-PEO-LPLG triblock copolymers: protein stabilization and in-vitro release properties.

artículo científico

Estimation of shear load sharing in moderately degenerated human lumbar spine.

artículo científico publicado en 2013

European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing.

artículo científico

Extra- vs. intramedullary treatment of pertrochanteric fractures: a biomechanical in vitro study comparing dynamic hip screw and intramedullary nail

artículo científico publicado en 2015

Factors influencing taper failure of modular revision hip stems

artículo científico publicado en 2018

Failure of the human lumbar motion-segments resulting from anterior shear fatigue loading.

artículo científico publicado en 2016

Femoral component loosening after hip resurfacing arthroplasty.

artículo científico publicado en 2010

Finite element analyses of human vertebral bodies embedded in polymethylmethalcrylate or loaded via the hyperelastic intervertebral disc models provide equivalent predictions of experimental strength

artículo científico publicado en 2014

Fluid transfer as a mechanism leading to endotension.

artículo científico publicado en 2010

Frame dislocation of body middle rings in endovascular stent tube grafts

artículo científico publicado en 1999

Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty.

artículo científico publicado en 2011

Head Taper Corrosion Causing Head Bottoming Out and Consecutive Gross Stem Taper Failure in Total Hip Arthroplasty

scientific article published on 24 July 2018

High amplitude direct compressive strain enhances mechanical properties of scaffold-free tissue-engineered cartilage.

artículo científico publicado en 2011

High cycle fatigue behaviour of functional spinal units

artículo científico publicado en 2010

High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication

artículo científico publicado en 2012

Homemaker service to mothers at the time of confinement

artículo científico publicado en 1950

How to proceed with asymptomatic modular dual taper hip stems in the case of acetabular revision

scientific article published on 02 March 2020

Hybrid Instrumentation in Lumbar Spinal Fusion: A Biomechanical Evaluation of Three Different Instrumentation Techniques

artículo científico publicado en 2017

Improvements in Vertebral Body Strength Under Teriparatide Treatment Assessed In Vivo by Finite Element Analysis: Results From the EUROFORS Study

article

In vitro characterisation of the biomechanical properties of the subchondral mineralised zone of lumbosacral facet joints.

artículo científico publicado en 2013

In vivo quantification of the apical fixation forces of different mitral valved stent designs in the beating heart

scientific article published on 29 October 2014

Increase in facet joint loading after nucleotomy in the human lumbar spine

artículo científico publicado en 2014

Influence of 3D QCT scan protocol on the QCT-based finite element models of human vertebral cancellous bone.

artículo científico publicado en 2014

Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses

scientific article published on 08 September 2011

Influence of cementing the pin on resistance to fracture in hip resurfacing

artículo científico publicado en 2010

Influence of interface condition and implant design on bone remodelling and failure risk for the resurfaced femoral head.

artículo científico publicado en 2011

Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis

artículo científico publicado en 2011

Influence of the compliance of a patient's body on the head taper fixation strength of modular hip implants.

artículo científico publicado en 2017

Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing.

artículo científico publicado en 2014

Influence of time in-situ and implant type on fixation strength of cemented tibial trays - a post mortem retrieval analysis.

artículo científico publicado en 2012

Influence of trabecular bone quality and implantation direction on press-fit mechanics.

artículo científico publicado en 2016

Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength.

artículo científico publicado en 2017

Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth

scientific article published on 01 November 2000

Interposition sleeve as treatment option for interprosthetic fractures of the femur: a biomechanical in vitro assessment

artículo científico publicado en 2015

Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results.

artículo científico publicado en 2007

Intramuscular pressure in the erector spinae and intra-abdominal pressure related to posture and load

artículo científico publicado en 1998

Learning metal artifact reduction in cardiac CT images with moving pacemakers

artículo científico publicado en 2020

Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate

artículo científico publicado en 2011

Long-term in vivo alterations of polyester vascular grafts in humans

artículo científico publicado en 1997

Malpositioning of the lag screws by 1- or 2-screw nailing systems for pertrochanteric femoral fractures: a biomechanical comparison of gamma 3 and intertan.

artículo científico publicado en 2014

Maximizing the fixation strength of modular components by impaction without tissue damage.

artículo científico publicado en 2018

Mechanical properties of native and tissue-engineered cartilage depend on carrier permeability: a bioreactor study

scientific article published on 19 March 2013

Migration and cyclic motion of a new short-stemmed hip prosthesis--a biomechanical in vitro study.

artículo científico publicado en 2006

Migration of two different cementless hip arthroplasty stems in combination with two different heads: a biomechanical in vitro study.

artículo científico publicado en 2006

Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty

artículo científico publicado en 2001

Mixing of two co-directional Rayleigh surface waves in a nonlinear elastic material.

artículo científico publicado en 2015

Modern gait analysis: a tool to improve shoes, insoles and the understanding of foot function

scientific article published on 01 January 1996

Modes of implant failure after hip resurfacing: morphological and wear analysis of 267 retrieval specimens.

artículo científico publicado en 2008

Morphologic analysis of periprosthetic fractures after hip resurfacing arthroplasty.

artículo científico publicado en 2010

Morphological and biomechanical analyses of the subchondral mineralized zone in human sacral facet joints: Application to improved diagnosis of osteoarthritis.

artículo científico publicado en 2015

Necessary precision levels for the subchondral mineralised zone thickness of the facet joint to optimise finite-element model

artículo científico publicado en 2013

Off-pump mitral valved stent implantation: comparison of apical and subannular fixation techniques.

artículo científico publicado en 2016

On the relationship between stature and anthropometric measurements of lumbar vertebrae.

artículo científico publicado en 2015

Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique.

artículo científico publicado en 2006

Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties.

artículo científico publicado en 2013

Possible role of H1 histone in the differentiation of mouse erythroleukemia cells

artículo científico publicado en 1990

Primary hip replacement stem taper fracture due to corrosion in 3 patients

artículo científico publicado en 2016

Primary implant stability after maxillary sinus augmentation with autogenous mesenchymal stem cells: a biomechanical evaluation in rabbits

scholarly article by Björn Riecke et al published 19 April 2011 in Clinical Oral Implants Research

Primary stability of uncemented femoral resurfacing implants for varying interface parameters and material formulations during walking and stair climbing

artículo científico publicado en 2009

Pseudotumor After Bilateral Ceramic-on-Metal Total Hip Arthroplasty: A Case Report.

artículo científico publicado en 2014

Pulsed lavage improves fixation strength of cemented tibial components

artículo científico publicado el 16 de octubre de 2010

Quantification of material loss from the neck piece taper junctions of a bimodular primary hip prosthesis. A retrieval study from 27 failed Rejuvenate bimodular hip arthroplasties.

artículo científico publicado en 2015

Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses

artículo científico publicado en 2015

Realistic loads for testing hip implants.

artículo científico publicado en 2010

Reasons for failure of hip resurfacing implants. A failure analysis based on 250 revision specimens

artículo científico publicado en 2008

Relationship between physical, biochemical and biomechanical properties of tissue-engineered cartilage-carrier-constructs.

artículo científico publicado en 2005

Sensing Cardiac Electrical Activity With a Cardiac Myocyte--Targeted Optogenetic Voltage Indicator

artículo científico publicado en 2015

Severe Wear and Pseudotumor Formation Due to Taper Mismatch in a Total Hip Arthroplasty: A Case Report.

artículo científico publicado en 2015

Sex differences in the morphological failure patterns following hip resurfacing arthroplasty

artículo científico publicado en 2011

Shear strength of the human lumbar spine.

artículo científico publicado en 2012

Squeak in hip endoprosthesis systems: An experimental study and a numerical technique to analyze design variants

artículo científico publicado en 2010

Static and dynamic loading measurements of the post-traumatic foot

artículo científico publicado en 1991

Stem taper mismatch has a critical effect on ceramic head fracture risk in modular hip arthroplasty

artículo científico publicado en 2016

Stent wire fractures and mesh loosening in explanted endovascular prosthesis

scientific article published on 01 January 2000

Technical strategies to improve tissue engineering of cartilage-carrier-constructs.

artículo científico publicado en 2009

The 12th "emed Scientific Meeting ESM", Providence (RI), USA, 14 to 17 August 2010

artículo científico publicado en 2011

The Influence of Cement Morphology Parameters on the Strength of the Cement-Bone Interface in Tibial Tray Fixation.

artículo científico publicado en 2016

The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty

artículo científico publicado en 2017

The condition of the cement mantle in femoral hip prosthesis implantations--a post mortem retrieval study

scientific article published on 01 April 2009

The development of the collagen fibre network in tissue-engineered cartilage constructs in vivo. Engineered cartilage reorganises fibre network

scientific article published on 05 April 2012

The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone.

artículo científico publicado en 2014

The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation

scientific article published on 01 January 2001

The effect of nucleotomy on facet joint loading - a porcine in vitro study

artículo científico publicado en 2013

The effect of nucleotomy on facet joint loading in the porcine lumbar spine.

artículo científico publicado en 2013

The influence of bandage characteristics and inter-individual application variations on underneath bandage pressures

artículo científico publicado en 1997

The influence of bone damage on press-fit mechanics

artículo científico publicado en 2014

The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations

artículo científico publicado en 2011

The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections

artículo científico publicado en 2012

The influence of friction and interference on the seating of a hemispherical press-fit cup: a finite element investigation

scientific article published on 01 November 1999

The influence of lateral heel flare of running shoes on pronation and impact forces

artículo científico publicado en 1987

The influence of material and design features on the mechanical properties of transpedicular spinal fixation implants.

artículo científico publicado en 2002

The influence of resting periods on friction in the artificial hip

artículo científico publicado en 2003

The influence of stem design on critical squeaking friction with ceramic bearings

scientific article published on 27 June 2013

The influence of stem taper re-use upon the failure load of ceramic heads

artículo científico publicado en 2015

The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study

artículo científico publicado en 2014

The role of inter-prosthetic distance, cortical thickness and bone mineral density in the development of inter-prosthetic fractures of the femur: a biomechanical cadaver study.

artículo científico publicado en 2014

The role of patient-mode high-resolution peripheral quantitative computed tomography indices in the prediction of failure strength of the elderly women's thoracic vertebral body

artículo científico publicado en 2014

The taper corrosion pattern observed for one bi-modular stem design is related to geometry-determined taper mechanics

artículo científico publicado en 2017

The taper disaster--how could it happen?

artículo científico

The use of water-jetting technology in prostheses revision surgery-first results of parameter studies on bone and bone cement

artículo científico publicado en 2000

Theoretical considerations and practical results on the influence of the representation of the foot for the estimation of internal forces with models.

artículo científico publicado en 1991

Time to augment?! Impact of cement augmentation on pedicle screw fixation strength depending on bone mineral density

artículo científico publicado en 2018

Transapical mitral valved stent implantation: comparison between circular and D-shaped design.

artículo científico publicado en 2014

Transapical mitral valved stent implantation: computed tomographic evaluation of different prototype designs

artículo científico publicado en 2014

Transapical mitral valved stent implantation: enhanced survival and decreased paravalvular leakages

artículo científico publicado en 2014

Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques

artículo científico publicado en 2018

Trunk muscle fatigue and associated EMG changes during a dynamic iso-inertial test.

artículo científico

Vibration transfer in the ball-stem contact interface of artificial hips.

artículo científico publicado en 2013

Volumetric analysis of osteoclastic bioresorption of calcium phosphate ceramics with different solubilities.

artículo científico publicado en 2010

Water jet discotomy with microinvasive approach--in vitro testing and initial clinical aspects of a new procedure

artículo científico publicado en 2001

Wear of a composite ceramic head caused by liner fracture.

artículo científico publicado en 2014

Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings.

artículo científico publicado en 2013

What can we learn from explanted endovascular devices?

artículo científico publicado en 2002

What is the risk of stress risers for interprosthetic fractures of the femur? A biomechanical analysis.

artículo científico publicado en 2012

["Basketball Foot"--long-time prognosis after peritalar dislocation]

artículo científico publicado en 2008

[A simplified procedure for mechanical testing of lumbar spinal fixation implants]

artículo científico publicado en 1999

[Comparison of different vertebral body prosthesis with reference to migration and primary stability in dorsoventral spondylodesis after corporectomy with and without laminectomy]

scientific article published on 01 May 2002

[Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses]

artículo científico publicado en 2005

[Damage to a hip endoprosthesis caused by high-frequency electrocautery]

artículo científico publicado en 2009

[Definition of pedicle malposition. Primary stability and loosening characteristics of pedicle screws in relation to position: spongious anchoring, cortical anchoring, perforation and malposition]

artículo científico publicado en 2002

[Effect of various cylinder diameters of implants for lumbar inter-corporeal spinal fusion on compressive strength on the FSU model]

scientific article published on 01 September 1998

[Late complications after alloplastic vascular replacement]

artículo científico publicado en 2001

[Load shift-total hip replacement--numerical and clinical evaluation of a new concept of adaptive stem fixation]

artículo científico publicado en 2003

[Mechanical study of potential ceramic implant materials for minimal invasive anterior lumbar interbody fusion]

artículo científico publicado en 1999

[Periprosthetic and interimplant femoral fractures: Biomechanical analysis]

scientific article published on 01 December 2015

[Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations]

scientific article published on 01 April 2002

[Squeaking as a cause for revision of a composite ceramic cup]

artículo científico publicado en 2011

[The pulsed water jet for selective removal of bone cement during revision arthroplasty]

artículo científico publicado en 2003

[Use of a water jet for synovectomy: in vitro study of feasibility].

artículo científico publicado en 2003

[Water jet cutting for bones and bone cement--parameter study of possibilities and limits of a new method]

artículo científico publicado en 2000

[Which hip articulation bearing for which patient? : Tribology of the future]

scientific article published on 01 December 2011